LAIYUAN Temperature Transmitter Data Sheet
| Input Types | RTD (PT100/PT1000), Thermocouple (K/J/E/S/T), mV, Ohm |
| Output Signals | 4-20mA, 0-10V, HART, RS485/Modbus |
| Accuracy | ±0.1% FS (RTD), ±0.2% FS (Thermocouple) |
| Operating Range | -40°C to +85°C (ambient),
-200°C to +1800°C (sensor dependent) |
| Power Supply | 12-36V DC (loop-powered), 24V AC/DC |
| Protection | IP67, ATEX/IECEx (optional), EMI/RFI shielding |
| Mounting | DIN rail, head-mounted, field-mounted |
| Certifications | CE, RoHS |
LAIYUAN Temperature Transmitter Description
LAIYUAN Temperature Transmitter can accurately measure temperature. It first senses temperature changes through thermocouples, etc., and then amplifies and linearizes the signals from RTDs, thermocouples and other temperature sensors through internal circuitry, converting them into standardized outputs (e.g., 4-20mA, HART, RS485) for easy transmission and subsequent control, making it the core device for industrial temperature monitoring.
As a professional supplier, LAIYUAN provides reliable temperature transmitters with ±0.1% accuracy, supporting Modbus/RS485 communication protocols, with IP67 protection and CE/ROHS certification. If you have temperature transmitter purchasing needs, please recognize LAIYUAN!
LAIYUAN Temperature Transmitter Types
Utilizes the thermoelectric effect for temperature measurement, ideal for high-temperature applications.
Operates based on resistance changes with temperature variations, offering high precision for low to medium temperature ranges.
Measures temperature through infrared energy detection, suitable for high-temperature or hazardous objects.
Combines the temperature sensing element and transmitter into a single unit for simplified installation.
Complies with explosion-proof standards, designed for use in flammable and explosive environments.
Features strong anti-interference capability and supports long-distance signal transmission.
- LAIYUAN Temperature Transmitter Wiring Guide
1)RTD Connection
2-wire system: direct connection of positive and negative poles (lower accuracy)
3-wire system: red (+), black (-), white (compensation)
4-wire: independent current/voltage channels (eliminates lead errors)
2)Thermocouple Wiring
Type K: red (+), yellow (-)
Type J: White (+), Red (-)
3)Power Supply and Output
Power supply: 24V DC (18-36V wide)
Signal: 4-20mA (brown +, blue -)
HART: Superimposed digital signal (same as 4-20mA line)
4)Attention
Ground the shielded cable at one end (PE end)
Avoid parallel with inverter/motor cables
LAIYUAN Custom Temperature Transmitter Manufacturer
LAIYUAN specializes in high-performance custom temperature transmitters to meet your exact industrial requirements. With over 10 years of expertise, LAIYUAN provide precision signal conditioning solutions for harsh environments, ensuring reliable temperature monitoring and control.
LAIYUAN supports -200℃~1800℃ full range temperature transmitter customization, and also supports ±0.05% ultra-high accuracy customization. LAIYUAN has a fully automated production line, which can quickly put the customer’s solution into production, if you are looking for a temperature sensor supplier, LAIYUAN will be your most reliable choice!

LAIYUAN Temperature Transmitter Benefits
1)High accuracy: ±0.1℃ measurement, A-class sensor + anti-interference design
2)Multi-function: compatible with thermocouple/ RTD, intelligent calibration
3)High reliability: -40℃~85℃ working, IP68/ATEX certification
4)Easy to install: integrated design, threaded/flange mounting
5)Flexible output: 4-20mA/RS485/HART protocol optional
6)Customized solutions: high temperature resistant / sanitary / miniaturized design
7)Cost-effective: 30% cost savings, 20% reduction in energy consumption
Installation Notice of LAIYUAN Temperature Transmitter
1)Position selection: avoid strong electromagnetic interference sources, stay away from vibration, high temperature or corrosive environments, and ensure that the measurement point is representative.
2)Installation method: Threaded or flange mounted, make sure the probe is in full contact with the measured medium (e.g. inserted into the center of the pipe).
3)Wiring specification: according to the instructions for wiring, shielded wire grounding to prevent interference, power and signal wires separately.
4)Protective measures: outdoor installation plus protective box, moisture and dust; flammable environment requires explosion-proof certification.
5)Calibration and verification: test the output signal after installation, and verify whether the output signal matches the actual temperature or not.

Related Products
Order Parameters of LAIYUAN Temperature Transmitter
1)Input type: thermocouple (e.g. K type, E type) or RTD (e.g. PT100, Cu50).
2)Measuring range: e.g. -50~300℃, need to match the actual working condition.
3)Output signal: 4-20mA, 0-10V, RS485, etc.
4)Accuracy level: e.g. ±0.2%FS.
5)Power supply: 24VDC or 220VAC, etc.
6)Installation method: threaded (M20×1.5), flange or rail type.
7)Protection requirements: IP65, explosion-proof grade (Ex dⅡCT6, etc.).
LAIYUAN provides you with advice for selection:
- Selection of protection according to the environment
- Select model according to accuracy
- Selection of outputs according to integration requirements
FAQ
- Sensor Match – Select RTD (PT100) or thermocouple (K-type) based on range/accuracy needs.
- Output Type – Pick 4-20mA, HART, or Modbus for your control system.
- Environment – Consider IP rating (e.g., IP67) or explosion-proof (ATEX) for harsh conditions.
LAIYUAN Digital and analogue temperature transmitters differ in 5 ways. Analogue (4 – 20mA) uses continuous current, has ±0.2% FS accuracy, one – way comm., easy install, low cost, suits legacy projects. Digital (HART/Modbus) uses data packets, has ±0.1% FS accuracy, two – way comm., needs compat. sys., high cost, fits smart setups. LAIYUAN offers both, welcome to contact us!
LAIYUAN have a wide range of models designed specifically for different environments. Some of our products can work in extreme temperatures ranging from – 40℃ to 85℃, which can meet the temperature measurement requirements of special scenarios such as polar research, high temperature industrial furnaces and so on.