LAIYUAN T Type Thermocouple Features
- High accuracy (0.5°C or ±0.4%), high sensitivity
- Armored construction impact resistance, fast response (0.1~0.5 seconds)
- High accuracy (0.5°C or ±0.4%), high sensitivity
- Armored construction impact resistance, fast response (0.1~0.5 seconds)
- Basic Specification
- Order Parameters
| Thermocouple Type | T |
| Electrode Material | Positive: Copper (Cu, ≥99.95% purity)
Negative: copper (Cu55%-Ni45%) |
| Temperature Range | -200°C ~ +350°C ( normal )
-200°C~ +400°C (short-term limit, limited use) |
| Tolerance Levels | Class 1: ±0.5°C or ±0.4%
Class 2: ±1.0°C or ±0.75% (IEC 60584) |
| Thermal Electric Potential Rate | Approx. 43 µV/°C (good linearity) |
| Insulation | PTFE (-60°C~260°C)
Fiberglass (-200°C~400°C) Ceramic (high temperature special needs) |
| Sheath Type | Armored Type ( stainless steel, Inconel)
Bare wire Type (non-corrosive environments) |
| Environment | Oxidizing, reducing, inert atmosphere |
| Cold Compensation | Supplied with T-type compensation wire or electronic compensation module |
- type thermocouples can be customized according to customers’ needs, and the production will be processed according to the drawings or text descriptions provided by you. When placing an order, you need to provide the following parameters:
- Probe diameter
- Probe length
- Working environment and temperature range
- Connection (such as thermocouple head or leading cable),
- Other accessories or not
- Specific quantities
LAIYUAN T Type Thermocouple Applications
LAIYUAN T Type Thermocouples offer excellent low temperature performance, lower cost, and flexible customized protection, are certified by IEC/ASTM, and are suitable for low to medium temperature, as well as high-precision scenarios:
- Ultra-low temperature monitoring: for liquid nitrogen/liquid oxygen storage (-200°C level), superconductivity experimental equipment, strong stability, alternative to high-cost platinum resistance.
- Food and medicine: sterilization cabinets, cold chain transportation and constant temperature box temperature control.
- Industrial manufacturing: plastic injection molding machine, HVAC system monitoring, economical and practical, suitable for automated signal transmission.
- Scientific research experiments: environmental test chamber high and low temperature cycle test, armored probe fast response (<0.5 seconds), vibration interference resistance.
- Medical equipment: medical sterilizer, blood storage, biocompatible design, to protect medical safety.
- Energy and environmental protection: refrigerated logistics, liquid hydrogen storage and monitoring, PTFE insulation and moisture-proof, adapting to complex working conditions.
LAIYUAN Type T Thermocouple VS Type K Thermocouple
- Materials and Temperature Ranges
T Type : Constructed of copper (Cu) and copper-copper (Cu-Ni alloy), designed for ultra-low to medium temperatures, with a routine measurement range of -200°C ~ +350°C (short-term up to 400°C), and excellent low-temperature stability.
K Type: Adopting nickel-chromium (Ni-Cr) and nickel-aluminum (Ni-Al) alloys, adapting to a wider high-temperature range, with a routine measurement range of -200°C ~ +1260°C (short-term up to 1350°C), and have a stable performance in high-temperature oxidizing environments.
- Accuracy and Sensitivity
T Type: Low-temperature accuracy up to ±0.5°C (Class 1), thermoelectric potential rate of 43 µV/°C, linear output characteristics to simplify signal processing.
K Type: Accuracy of ±1.5°C (Class 1) in the high temperature range, with a sensitivity of about 41 µV/°C, but with additional compensation for non-linear errors.
- Environmental Adaptability
T Type: Advantage: Adaptable to oxidizing, inert, vacuum and humid environments (e.g. PTFE insulation against moisture), suitable for liquid nitrogen storage, medical sterilization and other scenarios.
K Type: Advantage: resistant to high temperature oxidation (e.g. furnace, boiler), suitable for industrial high temperature monitoring.
- Cost and Response Speed
T Type: Low material cost, economical and practical; armored version of the fast response (fine diameter probe up to 0.1 ~ 0.5 seconds).
K Type: Nickel-based alloy cost is higher, but high temperature cost performance is better than precious metal thermocouple; response is slightly slower than T type.
Consider the temperature range, accuracy requirements, environmental conditions, response time, cost, and output characteristics. Match the thermocouple’s capabilities to these factors. For example, choose a T – type for low – temperature, a K – type for a wide range, and an S – type for high accuracy in specific applications.
The response time is determined by the probe construction and typical ranges are as follows:
Armored type: T90 about 0.1 to 0.3 seconds (in liquids) for diameters of 0.5 to 1.0 mm; about 0.5 to 2 seconds (in gases) for diameters of 1.5 to 3.0 mm.
Bare type: no sheath thermal resistance, faster response (but fragile).
Key affecting factors:
Probe diameter: smaller diameter, lower heat capacity, faster response.
Sheath material: stainless steel (fast thermal conductivity) is superior to Inconel (high temperature resistance).
Media contact: immersion depth ≥ 10x diameter in liquids, high flow rates required in gases.
LAIYUAN T Type Thermocouple insulation materials are adapted to the temperature and environment:
PTFE (polytetrafluoroethylene): corrosion and moisture resistant, suitable for -60°C to 260°C (e.g. humid, chemical environments).
Fiberglass: High temperature resistant, covering -200°C to 400°C, suitable for oxidizing/inert atmospheres.
Ceramic (alumina): Ultra-high temperature insulation (short-term up to 800°C) for special high temperature scenarios.
Armored version with additional metal sheath (stainless steel/Inconel) for increased mechanical protection. Selection is based on temperature, medium corrosivity and flexibility requirements.