Key Features
- Installation Without a Long Drilled Bore
- Accessible Removal and Maintenance
- Contact Established by the Slot and Clamp
- Square and Rectangular Profiles
Product Overview

Laiyuan’s square cartridge heater offers a surface-slot installation option for equipment where a long drilled bore is impractical. A square or rectangular body sits in a matching milled slot and is secured by a removable retaining plate.
The square cartridge heater range includes standard sections and custom profiles for long heated components and compact machine interfaces. Laiyuan specifies the active heating length, electrical rating and connections around the equipment drawing.
Product Customization
For a square cartridge heater, the slot drawing is the starting point. Provide width, depth and available length together with the retaining plate arrangement and the area requiring heat.
Match the Profile to the Existing Structure
Laiyuan can customize square or rectangular dimensions around the equipment slot. The standard sizes provide starting options; other profiles can be assessed for the required installation.
Coordinate Heating and Connections
Provide the supply voltage and type, required wattage or heating objective, and operating temperature. Laiyuan reviews output with effective heated length and section dimensions. Internal or external connections, lead length and protection materials can be specified; Type K or Type J thermocouples provide feedback to a compatible external controller.
Identify Replacement Dimensions
For a replacement square cartridge heater, include the existing component drawing or measured dimensions, fitting clearances and connector details. Identify any changes from the original component so they can be reviewed before quotation.
For a quotation, send the slot drawing, section dimensions, overall and heated lengths, voltage, wattage or heating objective, operating conditions, lead requirements, sensor needs and quantity.


OEM Enquiries and Technical Consultation at Laiyuan
Laiyuan focuses on OEM production and offers free consultation for customer-defined orders. For a square cartridge heater inquiry, identify whether the requirement is a new equipment build or an existing part replacement, and provide the required quantity and date.
A square cartridge heater quotation can then be discussed against the submitted requirements, including any unresolved design questions. Standard lead time is 7–9 business days, with special-order expedited production subject to confirmation. Send the equipment drawing to Laiyuan(jane@china-laiyuan.com) to start the review.
Key Features
A square cartridge heater is accessible from the slot opening when the retaining plate is removed. This can assist installation and replacement where the equipment provides enough access to the body and connections.
Removal space and the lead route should be considered at the design stage. Thermal exposure can affect the fit over time, so the removable plate does not guarantee effortless removal in every installation.
Close-fitting slot dimensions and an appropriate clamping arrangement support heat transfer into the heated component. The profile alone does not establish a universal heat-transfer efficiency; installation contact remains important.
The square cartridge heater range includes several standard cross-sectional dimensions and custom profiles. Swaged square and rectangular constructions can be assessed for higher thermal loads within the specified design requirements.


A high density cartridge heater can be evaluated where the equipment’s heating task calls for a higher-load component.

Output is assessed against the platen material, thickness and required heating response.

A high density cartridge heater can be assessed for positions needing higher local heat input within an existing tooling layout.
Technical Specifications
These square cartridge heater options are configured around the milled slot, heated length and electrical requirement. Cross-sectional values below are width × height dimensions, not area values.
| Parameter | Specification / Available Options |
| Square sections | 5 × 5, 6 × 6, 8 × 8, 10 × 10, 12 × 12, 16 × 16 or 20 × 20 mm; customized |
| Rectangular sections | 18 × 8.5, 19 × 8, 15.8 × 6.3, 22 × 8 or 12 × 6 mm; customized |
| Length | ≥100 mm |
| Voltage | 12–690 V; rated voltage and supply type specified for the equipment |
| Surface watt density | 1.0–20.0 W/cm²; application-dependent |
| Total wattage | Customized according to dimensions and heating requirements |
| Connection construction | Internal lead or external connection |
| Lead construction | Silicone/fiberglass-insulated leads; pure nickel conductor lead options with stated 500 °C or 800 °C ratings, subject to insulation and termination confirmation |
| Lead length | Standard: 300 mm; custom lengths available |
| Lead protection materials | Metal braid or flexible metal conduit |
| Temperature sensing | Type K or Type J thermocouple options |
| Installation | Milled slot with an appropriately designed retaining / clamping plate |
Lead temperature ratings do not establish the operating temperature of the complete square cartridge heater. Profile size, watt density, thermal contact and the connection conditions are reviewed together for the selected configuration.