What is RTD Compensating Cable?
LAIYUAN RTD Compensating Cable is a specialized connection cable designed for use with RTD sensors. It is primarily used to transmit temperature signals and eliminate measurement errors caused by the cable’s resistance. For example, a PT100 has a resistance of 100 Ω at 0°C. A temperature controller sends a weak current to the sensor and calculates the resistance value by detecting the voltage drop, thereby determining the corresponding temperature. Standard connection cables have inherent resistance, which is superimposed on the sensor’s resistance, leading to significant errors in temperature readings. LAIYUAN RTD Compensating Cable is specifically designed to address this issue and are compatible with 2-wire, 3-wire, and 4-wire connection configurations.

Designed specifically for extreme high-temperature industrial environments such as furnaces and metallurgical plants, with a maximum temperature resistance of +400°C

Withstands temperatures from -60°C to +260°C, offering excellent chemical resistance and stable dielectric properties

With a temperature range of -20°C to +105°C, this cable is suitable for general indoor wiring and control cabinet installations
Supports a wider temperature range of -50°C to +200°C and offers excellent flexibility, making it suitable for use in ovens and boilers
Feature Box

Low and stable wire resistance—minimizes temperature reading drift

3-wire and 4-wire designs compensate for wire resistance to achieve laboratory-grade accuracy

Adaptable to complex environments and resistant to electromagnetic interference

Ensure long-lasting durability and stable measurement performance
Who Needs RTD Compensating Cable
In the field of process control, RTD compensating cables ensure temperature stability within ±0.1°C in chemical reactors, distillation columns, and storage tanks;
In the power generation sector, RTD compensating cables are used to monitor turbine bearing temperatures and boiler feedwater conditions;
RTD compensating cables meet strict hygiene and accuracy standards in pharmaceutical production (sterilizers, fermenters, cleanrooms) and food and beverage processing (pasteurization, cold chain monitoring);
RTD compensating cables are used in HVAC and building automation systems for monitoring air handling units and chillers;
In constant-temperature baths, environmental test chambers, and material testing, this series of cables also provides laboratory-grade measurement accuracy.

Company Advantage


LAIYUAN is a professional and reliable manufacturer of RTD Compensation Cables, with over 10 years of industry experience. We operate our own production facility in Jiangsu and serve a wide range of customers in the chemical, power generation, pharmaceutical, and other precision industrial sectors. LAIYUAN offers factory-direct pricing and supports both standard-length orders and custom cutting services to meet diverse procurement requirements.
LAIYUAN adheres to strict quality control standards, with every batch of products undergoing rigorous testing. This includes precise conductor resistance matching within a 0.5% tolerance range, as well as high insulation resistance and high-voltage dielectric testing, to ensure stable and reliable cable performance.
In addition, LAIYUAN offers flexible custom manufacturing services to meet specific requirements for wire gauge, color coding, and jacket materials, providing highly tailored temperature measurement cable solutions for various industrial applications.
- Data sheet
| Conductor Material | High-purity tinned copper / silver-plated copper |
| Wire Gauge
|
20 AWG (0.5 mm²), 18 AWG (0.75 mm²), 16 AWG (1.0 mm²), 14 AWG (1.5 mm²) |
| Number of Cores | 2-core, 3-core, 4-core |
| Configuration | 2-wire, 3-wire (most common), 4-wire (precision) |
| Insulation Material | PVC (105°C), Silicone rubber (200°C), PTFE / Teflon (260°C), Fiberglass (400°C) |
| Shielding | Aluminum foil + tinned copper braid, optional dual shield
Drain Wire Included (all shielded versions) |
| Outer Jacket | PVC (standard), LSZH (low smoke zero halogen), PUR (mechanical protection) |
| Conductor Resistance | ≤ 0.1Ω per meter at 20°C (20 AWG), matched pairs within 0.5% |
| Insulation Resistance | > 500 MΩ·km |
| Voltage Rating | 300 V |