ptc cartridge heater_Laiyuan

Laiyuan PTC cartridge heater offers self-regulating liquid heating, immersion and flow-through designs, and custom OEM options. Request a quote.

Key Features

  • Power Responds to Element Temperature
  • Reduced Dependence on Frequent Switching
  • Different Liquid Heating Arrangements
  • Material and Surface Area Choices

Product Overview

Laiyuan’s PTC cartridge heater uses a positive temperature coefficient element for primarily liquid-heating applications. Immersion, flow-through and selected external pipe-mounted arrangements can be assessed for the equipment.

A PTC cartridge heater is selected for the liquid and operating conditions, not from a single constant wattage. The model tables distinguish power in water at 25 °C from no-water reference temperatures; neither value defines every point in the heating cycle.

Product Customization

For a PTC cartridge heater inquiry, provide liquid composition, initial and target temperatures, mass or flow rate, required heating time, supply voltage and installation drawing.

For a tank, specify the immersed dimensions and fitting. For flow-through equipment, provide the passage and flow requirements. Sheath material, body length, mounting, optional thermocouple and temperature switch are coordinated within the assembly.

State the preferred construction material and any food-contact, corrosion or long-term exposure requirements. Aluminum suitability for prolonged water service must be reviewed; alternative materials are not universally compatible.

A PTC cartridge heater with a lower characteristic temperature may require greater heat-transfer area to achieve the desired useful output. Laiyuan reviews this tradeoff with the heating requirement instead of selecting only from the highest listed power.

Model Identification and Order Acceptance at Laiyuan

Laiyuan offers reference PTC cartridge heater models as well as customer-defined configurations. For a catalogue inquiry, identify the exact model code and requested mounting option. Confirm the final order identifier before purchasing; similar dimensions do not establish that two codes represent the same build.

For a custom PTC cartridge heater order, agree the conditions under which quoted output will be evaluated. Record supply voltage, test medium and temperature, and the relevant installation or flow conditions so the acceptance requirement is distinct from a general heating-time estimate.

Standard lead time is 8~11 business days, with expedited production available for special orders after confirmation. Send Laiyuan(Email: jane@china-laiyuan.com /WeChat / WhatsApp: +86-15851048592) your drawing, operating requirements and quantity to request a configuration review and quotation.

Key Features

At a fixed voltage, a PTC cartridge heater follows P = V²/R. Resistance rises strongly in the element’s characteristic temperature region, reducing input power. The response depends on element temperature and heat transfer; it is not a guarantee of a fixed liquid temperature.

Where narrow temperature tolerance is unnecessary, self-regulation can reduce dependence on frequent on/off switching. Optional temperature sensing or switching may still be required by the equipment. Self-regulation does not replace fault protection, explosion protection or assessment of ignition risks.

Immersion units heat a tank directly. Flow-through designs use an internal liquid passage and require suitable flow or circulation. External pipe-mounted arrangements can be assessed where the existing pipe must remain intact.

Aluminum, stainless steel, copper and titanium options allow the construction to be considered against cost, medium compatibility and heat transfer. The PTC cartridge heater surface area and characteristic temperature are coordinated with the required output.

Water heating and auxiliary hot-water systems

A PTC cartridge heater can be evaluated for electric boilers, water-based space heating, solar hot-water assistance or heat-pump water-heater assistance.

Tank and circulation equipment:

A PTC cartridge heater configuration is assessed according to whether the liquid remains in a vessel or passes through the heating assembly.

Oil and fuel-related applications require a specifically qualified equipment design

suitability is not inferred from the PTC element alone.

Temperature maintenance and process liquids

he range can be assessed for baths, washing water, fermentation equipment, beverage warming and selected electroplating liquids. Sheath and sealing compatibility must be established for the actual medium; a material name alone does not qualify a finished assembly for food contact.

Technical Specifications

The PTC cartridge heater options below are confirmed for the complete assembly. Output and equilibrium temperature depend on supply and heat-transfer conditions.

Parameter Specification / Available Options
Sheath options Aluminum, SUS304, SUS316, Copper or Titanium
Voltage options 12 V, 24 V, 36 V, 72 V, 100–120 V, 220–240 V, 380 V or 600 V
Supply configurations Single-phase or three-phase, as specified for applicable AC designs
Heater length 50–800 mm
Surface temperature in air 50–260 °C, depending on the selected design and conditions
Mounting Thread or flange
Temperature sensing Thermocouple option
Temperature switch Available upon request
Power reference Listed model outputs are specified in water at 25 °C
Available profiles Flat aluminum, round aluminum or round SUS304 examples below; customized

 

For a PTC cartridge heater, no-water temperatures are reference conditions, not unrestricted dry-operation ratings. Confirm that the complete assembly, seals, wiring and equipment protection suit the intended condition.

Water Heating and Power Calculations

For water heated from T₀ to T without boiling, the ideal heat absorbed by the water is:

Q_water = M × c × (T − T₀)

Q_water is in joules (J), M is water mass in kilograms (kg), c ≈ 4200 J/(kg·°C), and T − T₀ is the temperature rise in °C. This excludes the container’s heat capacity and heat lost to the surroundings.

For average effective heating power P_water,avg in watts and time t in seconds:

Q_water = P_water,avg × t;   P_water,avg = Q_water ÷ t;   t = Q_water ÷ P_water,avg

If η is the effective fraction of electrical energy delivered to the water, 0 < η ≤ 1:

E_electrical = Q_water ÷ η;   P_electrical,avg = Q_water ÷ (η × t)

PTC electrical-to-heat conversion does not imply that all generated heat reaches the water. Since electrical power changes during warm-up, use the average over the interval, not only the listed output at 25 °C.

Evaporation and Continuous Flow Calculations

For water already at 100 °C, vaporized to saturated steam at 100 °C at approximately one atmosphere:

Q_vap = M × L_v;   L_v ≈ 2,260,000 J/kg

For average useful power during evaporation:

P_vap,avg = Q_vap ÷ t;   t = Q_vap ÷ P_vap,avg;   P_vap = ṁ × L_v

Here ṁ is the evaporation mass flow in kg/s. At 1 g/s = 0.001 kg/s, the ideal latent-heat requirement is 0.001 × 2,260,000 = 2260 W. It excludes initial water heating, container heating and heat loss.

If the water starts below its boiling point, include both stages:

Q_total = M × c × (100 − T₀) + M × L_v

For liquid water flowing through a heater without boiling, an initial useful-power estimate is:

P_water = ṁ × c × (T_out − T_in)

Actual electrical input must also account for losses and the PTC power response at the intended operating temperatures. These estimates support selection; they are not a guarantee of heating time.

 

Reference Size List of PTC Cartridge Heater :

The dimensions below describe the immersed section in millimetres. All listed examples are rated at 220 V. Power refers to the stated output in water at 25 °C; the no-water reference temperature is shown separately.

Flat Aluminum Models:

Model W × H × L (mm) Mount Dry Ref. Water 25 °C
LY-PTC-100L70W9.7T6-220V-AL 9.7 × 6 × 100 M14 250 °C 70 W
LY-PTC-100L150W13.2T6-220V-AL 13.2 × 6 × 100 M20 250 °C 150 W
LY-PTC-100L180W15.5T6-220V-AL 15.5 × 6 × 100 M22 250 °C 180 W
LY-PTC-100L350W16.5T11-220V-AL 16.5 × 11 × 100 M24 / flange 250 °C 350 W
LY-PTC-100L250W21.5T6-220V-AL 21.5 × 6 × 100 M25 / flange 250 °C 250 W
LY-PTC-100L450W21.5T12-220V-AL 21.5 × 12 × 100 M30 / flange 250 °C 450 W
LY-PTC-200L2KW21.5T24-220V-AL 21.5 × 24 × 200 M42 / flange 250 °C 2000 W
LY-PTC-200L1.8KW31T12-220V-AL 31 × 12 × 200 Flange 250 °C 1800 W
LY-PTC-200L500W32T7-220V-AL 32 × 7 × 200 Flange 250 °C 500 W
JSLv-200L1.8KW65T7-220V-AL 65 × 7 × 200 Flange 240 °C 1800 W

 

Round Aluminum Models:

Model D × L (mm) Mount Dry Ref. Water 25 °C
LY-PTC-100L100W8D-220V1-AL 8 × 100 M12 250 °C 100 W
LY-PTC-100L150W11D-220V1-AL 11 × 100 M14 250 °C 150 W
LY-PTC-100L200W16D-220V1-AL 16 × 100 M20 250 °C 200 W
LY-PTC-200L1.2KW23D-220V1-AL 23 × 200 M30 250 °C 1200 W
LY-PTC-200L1.8KW33D-220V1-AL 33 × 200 M42 250 °C 1800 W
LY-PTC-200L2.4KW40D-220V1-AL 40 × 200 M48 250 °C 2400 W
LY-PTC-500L6.5KW48D-220V1-AL 48 × 500 M56 250 °C 6500 W

 

Round SUS Models:

Model D × L (mm) Mount Dry Ref. Water 25 °C
LY-PTC-200L200W10D-220V-SUS 10 × 200 M14 / flange 240 °C 200 W
LY-PTC-200L250W12D-220V-SUS 12 × 200 M16 / flange 240 °C 250 W
LY-PTC-200L300D15D-220V-SUS 15 × 200 M20 / flange 240 °C 300 W
LY-PTC-200L400D20D-220V-SUS 20 × 200 M24 / flange 240 °C 400 W
LY-PTC-200L1.1KW25D-220V-SUS 25 × 200 M30 / flange 240 °C 1100 W
LY-PTC-400L2KW35D-220V-SUS 35 × 400 M42 / flange 240 °C 2000 W
LY-PTC-400L3.8KW45D-220V-SUS 45 × 400 M52 / flange 240 °C 3800 W
LY-PTC-500L5.5KW50D-220V-SUS 50 × 500 M56 / flange 240 °C 5500 W
LY-PTC-500L7KW50D-220V-SUS 50 × 500 M56 / flange 230 °C 7000 W

 

The tables provide reference dimensions and model options. Laiyuan can assess a custom configuration based on your requirements.