Key Features
- Two Structures for Different Tank Arrangements
- Sheath Materials Selected for the Medium
- Termination Protection Matched to Liquid Exposure
- Surface Load Matched to Heat Transfer Conditions
Product Overview

An immersion cartridge heater must match both the liquid being heated and the parts exposed to it. Laiyuan supplies two configurations: a threaded heater installed through the tank wall, and a fully submersible assembly with a molded silicone protective head and silicone leads.
Laiyuan specifies each immersion cartridge heater for the liquid composition, required output and tank installation. Threaded and fully submersible versions are separate configurations, not interchangeable installation methods.
Product Customization
For an immersion cartridge heater inquiry, provide liquid composition, concentration, operating temperature, tank dimensions and minimum operating level.
Define the Tank Interface
Provide the thread designation for a tank-wall connection, or state the required immersion depth and lead exposure for a submersible build. Include any pressure conditions.
Select the Heating Load
Fresh-water designs may use surface loads up to 12 W/cm² when conditions permit. For mineral-rich or well water, approximately 8 W/cm² is a starting recommendation. Oil applications generally call for loads below 3 W/cm², with lower values below 2 W/cm² considered for oils with more demanding heat transfer conditions.
Coordinate Dimensions and Leads
Define immersion cartridge heater overall length and active heated length separately. Show voltage, wattage and lead length on the tank drawing, including the operating liquid level.
For a quotation, provide liquid composition, target temperature, volume, required heating output or heating time, available voltage, tank connection, overall and immersion lengths, minimum operating liquid level, lead exposure conditions and quantity. Include pressure conditions where relevant and an installation drawing if available.


Liquid Exposure Acceptance Requirements at Laiyuan
Define the Exposure Test
For an immersion cartridge heater project requiring leak or immersion acceptance testing, specify the test medium, temperature, depth or pressure and duration. Agree acceptance criteria before production rather than relying on a general waterproof description.
Separate Electrical Acceptance Criteria
Record agreed test conditions with the immersion cartridge heater order specification. Where electrical acceptance checks are required, identify their limits and test conditions separately from liquid-exposure criteria.
Standard lead time is 7–9 business days; special-order expedited production requires confirmation. Contact Laiyuan to review applicable CE marking, RoHS and REACH documentation for the selected configuration.
Key Features
For a threaded immersion cartridge heater, the heated body enters the liquid while the fitting mounts through the tank wall. Full immersion instead allows the specified head and immersed lead section to contact compatible non-corrosive liquids.
SUS304 seamless tubing is a starting option for fresh water and compatible oils. SUS316L, Incoloy 800 or a PTFE-coated sheath can be considered for certain chemically aggressive media, while titanium is an option for seawater. Selection depends on the actual liquid composition and temperature.
The threaded lead exit uses epoxy resin; the submersible version uses a molded silicone head and specified silicone-insulated leads. Liquid, temperature, depth and exposure duration must be confirmed for these materials. Their names alone do not establish an IP rating.
The immersion cartridge heater output is selected from the required temperature rise, liquid quantity and heating time. The surface load must also match the medium’s ability to transfer heat.


A threaded immersion cartridge heater can be evaluated for direct water heating through a tank connection.

Lubricating oils, edible oils, olive oil and juices require review of additives and, where relevant, food-contact suitability.

An immersion cartridge heater can be assessed for these applications when the wetted materials suit the specified composition, concentration and temperature.
The immersion cartridge heater range below is customized for the liquid and installation. Final material, electrical and sealing options are confirmed as one compatible configuration.
| Parameter | Specification / Available Options |
| Sheath diameter | ≥8 mm |
| Overall length | ≥50 mm; customized |
| Rated voltage | 12V–690 V;Supply DC and AC |
| Surface watt density | 1.0–12 W/cm²; Selected according to the liquid |
| Total wattage | Customized according to heated length and liquid heating requirements |
| Installation structures | Threaded tank mounting or fully submersible silicone-head configuration |
| Sheath options | SUS304, SUS316L, Incoloy 800, titanium or PTFE-coated sheath, subject to medium compatibility |
| Threaded fitting gasket | Silicone or PTFE, selected for the installation |
| Threaded lead exit | Epoxy resin seal |
| Fully submersible termination | Molded silicone protective head; for compatible non-corrosive liquids |
| Lead materials | PTFE or Silicone rubber insulated leads; specified silicone-insulated leads for the submersible version |
| Lead length | Standard: 300 mm; custom lengths available |
| Thread and immersion length | Customized to the tank interface and equipment dimensions |
For an immersion cartridge heater, the immersion depth must keep the active heating section covered during operation. Full submersion of the termination is permitted only for the specified submersible construction; waterproof lead material alone does not establish that the complete assembly is suitable for immersion.