Key Features
- Integrated Heating and Temperature Switching
- Automatic Cutoff and Reset
- Optional Thermal Fuse
- Sealed Lead Exit and Flexible Mounting
Product Overview

Laiyuan’s cartridge heater with thermostat combines localized heating with an integrated automatic-reset temperature switch. It provides an on/off heating option for suitable liquid or mold installations.
A cartridge heater with thermostat can include an optional thermal fuse and customer-defined mounting or connections. The configuration is assessed for the equipment’s heating cycle rather than selected as a universal temperature-control assembly.
This series is not intended for free-air heating or PID-level temperature regulation.
Product Customization
For a cartridge heater with thermostat inquiry, provide the target process temperature, acceptable variation, heated material or liquid, and available installation space.
Specify cartridge heater with thermostat dimensions, supply type, voltage, wattage, mounting and leads. State the requested action and reset ratings and whether a thermal fuse is required; switching components must be suitable for the actual AC or DC load.
For suitable supply configurations, a European plug with a power indicator is available. The light provides a visible indication of power at the plug; it does not independently confirm heater output or diagnose a fault.
For a quotation, provide voltage, required wattage or heating objective, liquid or mold details, target temperature, acceptable temperature variation, dimensions, mounting arrangement, lead requirements and quantity. An installation drawing helps us turn these requirements into a configuration your engineering team can review.


Why Source from Laiyuan
Laiyuan supplies a cartridge heater with thermostat to several European companies for truck-mounted water tank applications. Supplied designs use 12 V or 24 V DC, a sealed tube opening, a black protective cap and silicone-insulated leads; some include a thermal fuse.
For a repeat cartridge heater with thermostat order based on an existing build, identify the approved reference and any changes to supply voltage, switch ratings or connections. These details allow the new inquiry to be reviewed against the original configuration rather than assuming all truck tank heaters are interchangeable.
Standard lead time is 7–9 business days, with expedited production available for special orders after confirmation. Contact Laiyuan(jane@china-laiyuan.com ,Wechat/Whatapp:+86-15851048592) to confirm the CE marking documentation, RoHS compliance information and REACH-related declarations applicable to the selected product.
Key Features
A cartridge heater with thermostat combines the heating element and temperature switch, reducing separate component mounting requirements. This arrangement suits compact OEM assemblies that need straightforward on/off heating.
For a cartridge heater with thermostat using a nominal 50 °C switch, the action range is 45–55 °C. The switch opens the heater circuit at its action temperature and closes at its reset point. The difference between these points determines the cooling interval before heating resumes.
An optional thermal fuse, such as a component with a nominal 80 °C rating, provides a non-resetting cutoff. It opens the circuit when its specified thermal conditions are reached, including if the thermostat does not interrupt heating. Its effectiveness depends on the selected rating, installation position and thermal contact; it does not replace system-level protection assessment.
The tube opening uses an adhesive seal to help limit moisture ingress. Silicone-insulated leads are commonly used, with insulation selection confirmed for the actual water or oil exposure and temperature. Threaded fittings, flanges, retaining plates and custom mounting options are available. Sealing does not establish an IP rating for the complete assembly.


Molds and compact OEM assemblies: A cartridge heater with thermostat can be evaluated where the machine design allows direct mounting of the combined heating and switching component.

Truck-mounted water tanks: A cartridge heater with thermostat can be assessed for an installation requiring integrated on/off heating from the vehicle’s DC supply.
Technical Specifications
Use the following cartridge heater with thermostat specifications to prepare your inquiry. Heater output and switching components are selected together; compatibility depends on supply type, voltage, load current, installation and required thermal response.
| Parameter | Specification / Available Options |
| Sheath diameter | ≥12 mm |
| Sheath length | ≥100 mm |
| Supply voltage | Up to 240 V; single-phase AC configurations and 12 V / 24 V DC designs, subject to switching component ratings |
| Rated wattage | Designed according to diameter, overall length, effective heated length and operating conditions |
| Temperature switch | Integrated automatic-reset thermostat |
| Action and reset temperatures | Selected from the component options below |
| Thermal fuse | Optional; rating selected for the application |
| Tube opening | Adhesive seal to help limit moisture ingress; complete assembly protection to be confirmed |
| Lead construction | Commonly silicone-insulated leads; suitability for temperature and water/oil exposure to be confirmed |
| Mounting options | Threaded fittings, flanges, retaining plates or custom structures |
| Insulation resistance | >100 MΩ |
| Intended installation | Liquid heating or molds with suitable thermal contact; not for free-air heating |
Selecting the Switching Temperatures
The switch in a cartridge heater with thermostat responds to temperature at its own installation location. Its nominal action rating does not guarantee that the entire liquid volume or mold has reached the same temperature. Thermal contact, heater placement and heat transfer conditions are considered when selecting action and reset settings.
Thermostat Action and Reset Temperature Options
The table lists the supplied component ratings. Values marked ≥ are retained as specified reset limits; confirm the actual reset point and switching differential for the selected component before production.
| Component Code | Action Temperature (°C) | Reset Temperature (°C) |
| 30 | 30 ± 3.5 | ≥20 |
| 35 | 35 ± 4 | ≥25 |
| 40 | 40 ± 4.5 | ≥30 |
| 45 | 45 ± 5 | ≥33 |
| 50 | 50 ± 5 | ≥35 |
| 55 | 55 ± 5 | 42 ± 6 |
| 60 | 60 ± 5 | 45 ± 8 |
| 65 | 65 ± 5 | 48 ± 10 |
| 70 | 70 ± 5 | 50 ± 12 |
| 75 | 75 ± 5 | 53 ± 14 |
| 80 | 80 ± 5 | 55 ± 15 |
| 85 | 85 ± 5 | 60 ± 15 |
| 90 | 90 ± 5 | 65 ± 15 |
| 95 | 95 ± 5 | 70 ± 15 |
| 100 | 100 ± 5 | 70 ± 15 |
| 105 | 105 ± 5 | 75 ± 15 |
| 110 | 110 ± 5 | 75 ± 15 |
| 115 | 115 ± 5 | 80 ± 15 |
| 120 | 120 ± 5 | 85 ± 15 |
| 125 | 125 ± 5 | 85 ± 15 |
| 130 | 130 ± 5 | 90 ± 15 |
| 135 | 135 ± 5 | 95 ± 15 |
| 140 | 140 ± 5 | 100 ± 15 |
| 145 | 145 ± 5 | 100 ± 15 |
| 150 | 150 ± 5 | 105 ± 15 |
| 155 | 155 ± 5 | 110 ± 15 |
| 160 | 160 ± 5 | 115 ± 15 |